I do the testing and calibration of the instrumentation.
  
    -   
RTD’s
   -   
Thermocouples
   -   
Pressure transmitters
   -   
Valves
   -   
RVDT’s 
   -   
LVDT’s 
  -   
Actuators
   -   
Etc.
 
  
  I have some bad experiences with smart transmitters! For example instruments with ranges of 0 to 10 Bara are used for measuring atmospheric pressure. I think that smart transmitters have caused a lot of damage to installations since they were introduced. Every technician with a Hart communicator can change ranges, Offsets and Gains so easily. The control does not now anything about it because it is only looking at a 4 to 20mA signal. This is why I prefer standard instruments for specific ranges instead of the smart bastards. Adjusting ranges can always be done on the control. I prefer to do the calibration on the instrument itself, but if it is not possible I will do it in the control.